Variable pump pressure adjustment steps

  1) Adjust the pressure of unloading valve DA10, relief valve DB10 or DB20 to the minimum.    2) Check in the slurry inlet valve and close the slurry outlet valve to the minimum, that is, the slurry flow rate of the pump is small at this time.    3) Start the motor, slowly adjust the relief valve DB10 or DB20 to adjust the mud pressure to be about 0.1Mpa-0.2Mpa less than the required pressure.    4) Slowly adjust the unloading valve DA10 until the unloading valve has pressure (that is, the pressure gauge corresponding to the unloading valve shows less than 0Mpa).    5) If the state cannot be reached, adjust the unloading valve and the relief valve according to the above steps 3 and 4 until this state.    6) After adjusting the unloading valve, tighten the nut. (Note: The pressure of the unloading valve should be zero at this time, if it is not zero, then slightly lower the pressure of the unloading valve, and the pressure will only be displayed when it reaches zero).   

Rainwater pumping station and confluence pumping station

  The basic characteristic of rainwater pumping station is large flow and small head, therefore. Axial-flow pumps are mostly used, and sometimes mixed-flow pumps are used. The general process flow of rainwater pumping station is as follows: Inlet pipe:'inlet gate well, grit tank, grid room, foretank, and catch basin' water outlet and one outlet pipe, outlet gate well and outlet. For combined pumping stations, the catch basin is generally sewage and rainwater combined, and the pump It can be set separately or shared. Basic types of pump rooms The rainwater pump house (combined pump house) is generally built together with the collection tank and the pump. According to whether the ditch pool and the pump are separated by unsuitable partition walls, they are divided into "dry room" and "wet room". The "dry room" pump room (as shown in Figure 5. Lo) is generally divided into three floors. The upper floor is the motor room. Install motors an

How to choose the model of gear pump

 Performance range: 2CY gear oil pump is suitable for conveying lubricating oil with viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / S (5-1500cst) or other liquids similar to lubricating oil and used in hydraulic rotating system without solid particles and fibers, without corrosiveness, temperature not higher than 80 ℃. LB refrigerator special gear pump: suitable for conveying no solid particles and fibers, no corrosion, temperature not higher than 80 ℃, viscosity 5 ~ 1500st Ch y gear pump: ch, CHY gear pump is used to transport the viscosity below 200 ° e (1500 MPa. S) of mechanical oil, turbine oil and other media with similar lubrication performance and properties, and the temperature is not higher than 120 ℃. K1p gear pump: pump displacement: cm3 / R. High efficiency, low energy consumption, convenient operation, easy maintenance, strong structure and long service life. HGP type gear pump: QT internal gear pump internal gear contact smooth, silent continuous operation. Its char

Analysis on the use stage of well furnace

 Analysis on the use stage of well furnace There are several stages in the operation of a well furnace: Furnace installation, exhaust and temperature rise: 1, after the well furnace to the temperature insulation 0.5~1h, make the temperature uniform, into the parts, hanging parts should be more than 10mm gap, to ensure that the gas unblocked. 2, the parts must be placed in the effective heating zone of the furnace tank, the upper end should not exceed the exhaust pipe, the lower end should keep a certain distance from the intake pipe, after installing the furnace exhaust time is about 20~60min. 3. The sample should be placed in three different positions: upper, middle and lower. 4, after the installation of the furnace, should immediately send infiltration agent exhaust (ethanol drops), when the temperature of the furnace to the specified temperature, in the outlet of the exhaust gas, such as the flame does not point, should increase the amount of infiltration agent or time